1988 Mercedes Benz 300CE (124 Chassis) Connecting Test Equipment and Reading Diagnostic Trouble Codes

Testing with the impulse counter should be carried out for rapid fault diagnosis. The
impulse counter output shows only existing faults, since the ACC system does not have
memory capabilities. If one or more faults are indicated, repair as necessary and repeat
the test. Be sure that fuse #7 is good, the battery voltage is between 11-14 volts and the
temperature selector wheel is set to 22°C.
1. Connect the impulse counter to the on-board diagnostic connector.
Black lead of the impulse counter to socket 1
Yellow lead of the impulse counter to socket 7
Red lead of the impulse counter to battery positive terminal.
2. Turn the ignition to the “ON” position.
The LED “U Batt” will be illuminated. If the LED “U BATT” does not illuminate,
check for voltage between socket 1 of the on-board diagnostic connector and
the positive terminal of the battery. If the voltage is not between 11-14 volts,
check for an open circuit or loose ground connection.
Test for voltage between socket 7 and socket 1 of the diagnostic connector.
The voltage should be 6 – 12 volts.
3. Depress the start button for 2 – 4 seconds.
Fault codes will be indicated by the number in the impulse counter display
window. Take note of the impulse display number.
Faults are displayed in ascending order.
The number 1 indicates that no faults are stored in memory.
During the impulse readout, The LED indicator in the fresh air/recirculation
switch will blink.
4. Repeat step 3 until all faults are indicated. After all fault codes have been
displayed, pushing the start button again for 2 – 4 seconds will repeat the fault code
readout sequence.

Source

Leave a Comment

DUCATI 620Sport Owner’s Manual

Hearty welcome among Ducati fans! Please accept our best compliments for choosing a Ducati motorcycle. We think you will ride your Ducati motorcycle for long journeys as well as short daily trips. Ducati Motor Holding S.p.A. wishes you smooth and enjoyable riding. We are steadily doing our best to improve our “Technical Assistance” service. For this reason, we recommend you to strictly follow the indications given in this manual, especially for motorcycle running-in. In this way, your Ducati motorbike will surely give you unforgettable emotions. Please contact our authorised service centres to have your motorcycle repaired or if you simply need advice.
[Read the rest of this entry...]

Leave a Comment

OPEL – Trouble shooting – OPEL / VAUXHALL Preface

OPEL - Trouble shooting – OPEL / VAUXHALL PrefaceTROUBLE SHOOTING OPEL / VAUXHALL 1 A0909032-1 Trouble shooting – OPEL / VAUXHALL Preface The program cassette in the Multi-Tester pro is the component which gives the diagnostic equipment its unique test performance. The program cassette can easily be changed to set the Multi-Tester pro up quickly for the diagnostic task at hand. The Multi-Tester pro software is available in two levels of functionality, Plus line and Pro line. This manual covers the operation of the Pro line cartridge. Although operation and display screens are identical for each line, please be aware that some of the functions described are not available on Plus line cartridges. The Plus line cartridge has the following functions: engine DTC:s and monitor list, airbag DTC:s, ABS DTC:s and service light resetting as well as snapshots. This fault-finding instruction describes the serial application for trouble shooting via the diagnostic connector on Opel and Vauxhall. Copyright AUTODIAGNOS
[Read the rest of this entry...]

Leave a Comment

DUCATI ST4s Owner’s Manual

When the ignition key is turned to OFF, the immobilizer inhibits engine operation. When the ignition key is turned back to ON to start the engine, the following happens:
1) if the CPU recognised the code, the CODE light on the instrument panel will flash briefly. This means that the immobilizer system has recognised the key code and enabled engine ignition. When you press the START button, the engine will start up.
2) If the CODE light stays on, it means that the code has not been recognised. When this is the case, turn the ignition key back to OFF and then to ON again. If the engine still does not start, try with another black key. If the other key does not work out either, contact the DUCATI Service network.
[Read the rest of this entry...]

Leave a Comment

DUCATI 749DARK Owner’s manual

In your own interest, and in order to guarantee product reliability, you are strongly advised to refer to a Ducati Dealer or Authorized Workshop for any servicing requiring particular technical expertise. Our highly skilled staff have access to the implements required to perform any servicing job at best, using Ducati original spare parts only as the best guarantee for full interchangeability, smooth running and long life.
[Read the rest of this entry...]

Leave a Comment

Ducati’s 900SS Raw riding sensation

Mike Hailwood drove kids like me mad by winning on a Ducati 900 at the 1978 TT and we’re the adults who desire these bikes today. The 900SS is a single-minded sportster that still stirs emotions, some of which don’t have a name.
[Read the rest of this entry...]

Leave a Comment

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES

1 QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES ...1 QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES (a) Applicability Quality assurance programs as described in paragraph (c) of this section are recommended for all diagnostic radiology facilities. (b) Definitions As used in this section, the following definitions apply: “Diagnostic radiology facility” means any facility in which an x-ray system(s) is used in any procedure that involves irradiation of any part of the human or animal body for the purpose of diagnosis or visualization. Offices of individual physicians, dentists, podiatrists,
[Read the rest of this entry...]

Leave a Comment

BASIC QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY

BASIC QUALITY CONTROL IN DIAGNOSTIC RADIOLOGYAAPM REPORT No. 4 BASIC QUALITY CONTROL IN DIAGNOSTIC RADIOLOGY American Association of Physicists in Medicine FOREWORD This document, “Basic Quality Control in Diagnostic Radiology”, is the fourth in a series of AAPM reports. This document is designed to enable technologists working with the guidance and supervision of a medical physicist to set up a viable quality assurance program in diagnostic radiology with minimal expense. The AAPM, through its Diagnostic Radiology Committee, plans to issue additional documents detailing physicist/engineer level
[Read the rest of this entry...]

Leave a Comment

Cytology of bronchial biopsy rinse fluid to improve the diagnostic

Cytology of bronchial biopsy rinse fluid to improve the diagnostic ...Eur Respir J 1998; 12: 1415–1418 DOI: 10.1183/09031936.98.12061415 Printed in UK – all rights reserved Copyright ©ERS Journals Ltd 1998 European Respiratory Journal ISSN 0903 – 1936 Cytology of bronchial biopsy rinse fluid to improve the diagnostic yield for lung cancer A. Rosell*, E. Monsó*, L. Lores*, X. Vilà*, M. Llatjós**, J. Ruiz*, J. Morera* aa Bronchoscopic techniques performed for the diagnosis of endobronchial lesions include bronchial biopsy and some accompanying cytological procedures such as needle aspiration and bronchial
[Read the rest of this entry...]

Leave a Comment

Ducati Suite- Rear Suspension Adjustment

The good ol’ Monster rear suspension: single adjustable Boge-Sachs rear shock. It’s gotten a bad rap as an underperformer, but it is still a quality piece with much better adjustment than many other sportbike shocks allow. Then again, why wouldn’t it? It’s a Ducati.
[Read the rest of this entry...]

Leave a Comment