Free PDF Manual Guide

User Manuals – Owners Manual – User Guide

O2™ : Silicon Graphics 1600SW Flat Panel Monitor Adapter Installation Guide

This guide tells you how to install the Silicon Graphics 1600SW flat panel monitor adapter board in the O2 workstation. There are two classes of O2 workstations, the R5000, and the R10000. The 1600SW flat panel monitor adapter can be installed in either class of O2 workstation.
The guide is organized as follows:
• Chapter 1 describes how to install the adapter board in your O2 workstation.
• Chapter 2 describes how to adjust the flat panel timing tables and how to calibrate color for the 1600SW flat panel monitor.
• Chapter 3 provides troubleshooting information, technical specifications, and regulatory statements.
• The glossary defines many of the terms used in the manual.
[Read the rest of this entry...]

Leave a Comment

Forge Motorsport Golf 1.8T, SEAT Leon 1.8T and Audi A3 1.8T DV fitting guide

Tools required: – Cross head screwdriver, Flat blade screwdriver, 6mm and 7mm hose
clip drivers, Sharp craft knife.
1/ Open bonnet/hood. Remove the plastic engine cover. Remove the hose running between the throttle body housing and the top intercooler connection (bottom left hand corner of the picture above)
2/ Fit the new hose with the 25mm spout as shown above. If the hose is too long it will probably become misshapen, if this happens then remove and simply trim the ends with a sharp craft knife, only remove 10-15mm at any time and refit to check the hose shape after each cut if required. Once happy with the fit then secure with the hose clips supplied.
[Read the rest of this entry...]

Leave a Comment

CAT-303 Installation and Parts Manual

Installation Environment
1) The distance between the unit and outside wall or other goods should be kept over 200mm.The unit should be put in well-ventilated area and its temperature is within -10℃~+40 .℃
2) Check air supply pipeline of the unit and use air source with 3~10 bar to supply for the unit. When connecting the air source, please check if there is leakage in connector for air source and ensure that a certain distance between the air hose and heat source should be kept.
3) To ensure safety. Before connecting the air source, please confirm that the air pressure adjusting valve is closed. Never point the air outlet to personnel.
[Read the rest of this entry...]

Leave a Comment

Floating Pump Honda Owner’s Manual

In order to use the Floating Pump to pump water from a dam, swimming pool or large tank into your Silvan spray equipment, simply attatch the 2 ½” BSP fitting on the 64mm lay flat hose supplied, to the 2 ½” BSP outlet of the Floating Pump. Next, either attatch the outlet end of the hose to the inlet of your spray equipment using the camlock fitting supplied, or simply place the outlet of the lay flat hose into the fill opening on the spray equipment. Place the Floating Pump into the dam, swimming pool or tank, ensuring the water is deep enough below the pump inlet to prevent mud etc from being drawn up from the bottom of the dam, swimming pool or tank and into the pump.
[Read the rest of this entry...]

Leave a Comment

1999.5 – 2005 Volkswagen Golf/GTI 2.0L 4 Cyl. Cold Air System Installation

Installing the AEM Cold Air System
a) When installing the AEM intake, DO NOT completely tighten the hose clamps, MAF sensor assembly or the mounting tab hardware until instructed to do so later in these instructions.
b) Install the rubber mount in the outermost (towards driver’s side of vehicle) hole to the rear of the large opening behind the headlight. Insert the rubber mount from below (Fig. 16) and secure it with a large fender washer and lock nut from the top. (Fig. 17)
c) Place a large fender washer on the stud that originally secured the lower intake tube in place. (Fig. 18)
d) Re-install the MAF sensor into the plastic intake hose, rotating the electrical connector to the original position. Use the original spring hose clamp. Note: it is possible to install the MAF sensor backwards. DO NOT INSTALL BACKWARDS. Make sure that the end with the flange (originally in the airbox) is still facing away from the throttle body. If you are still unsure, there is an arrow with the word “flow” molded into the MAF sensor body. (Fig. 19)
[Read the rest of this entry...]

Leave a Comment

VAUXHALL / OPEL CORSA Installation Instruction Sheet

Installation Instruction Sheet - VAUXHALL / OPEL CORSA 1.2, 1.4 ...VAUXHALL / OPEL CORSA 1.2, 1.4 Spi 60BHP 1993-99 57-0298 Instruction Sheet A2054-796 Page 1 of 2 PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE FITTING THE KIT. Note: the kit fits both models. Photo A Photo B 1. Unclip and remove the intake hose from the air box assembly. 2. Remove the air box hot air flap vacuum hose from the rear of the intake housing. Blank off the vacuum outlet pipe with the rubber plug supplied. 3. Unclip and remove the intake scoop from the front cross member and air box assembly. 4. Remove the flexi hose from between the exhaust manifold and the air box hot air flap. 5. Remove the air box assembly from the front mounting rubber, then slide the assembly out of the rear mounting grommets. Remove the assembly from the car. 1. Fit the new mounting bracket to the original rear air box mounting grommet
[Read the rest of this entry...]

Leave a Comment

1992–1995 Honda Civic Cold Air System Installation Instructions

The AEM Cold Air System is the result of extensive development on a wide variety of cars. Each system is engineered for the particular application. The AEM Cold Air System differs from all others in several ways. We take the inlet air from outside of the engine compartment where the inlet air is considerably cooler than the hot underhood air. The cooler inlet air temperature translates to more power during the combustion process because cool air is denser than warm air. AEM has conducted extensive inlet air temperature studies and we have seen temperature reductions of up to 50 degrees by pulling air from outside of the engine compartment. The air mass flow to the engine is increased because of the increased airflow and reduced inlet temperature, which translates to more power. The AEM Cold Air Systems are 50 states Street Legal (some model and years still pending) and come with complete instructions for ease of installation.
[Read the rest of this entry...]

Leave a Comment

NHP (Small) Series Gas operator’s Manual

Carefully unpack your new Amazing Machinery™ pressure washer by removing the banding and cardboard box from pallet. Remove the pressure washer from the pallet and check for any physical damages that may have occurred during shipment. Check for all parts specified and shown in figure 1.
[Read the rest of this entry...]

Leave a Comment

Installation instructions for Stratmosphere HyperBoost Valve

Bob and I appreciate your purchase of your HyperBoost Valve from Stratmosphere. Please read these instructions prior to installation so that you can enjoy a simple and quick installation of your new HyperBoost valve! –Pete
What’s included with your package:
• One HyperBoost diverter valve
• Two medium sized hose clamps
• One small hose clamp
• One instruction sheet (you are reading it)
[Read the rest of this entry...]

Leave a Comment

GX390 13HP HONDA ENGINE Operation, Maintenance & Parts Manual

Steps for Pressure Operation
1. Release hose from hose reel
2. Attach wand to hose reel
3. Start Honda Engine—see following instructions
4. Depress handle on wand to release the pressurized water
5. Direct pressurized water at area to excavate—working the wand in a rotating motion
[Read the rest of this entry...]

Leave a Comment

?>